摘要:分析給水泵變頻調(diào)速節(jié)能原理;針對鍋爐給水泵改由變頻器控制后存在的汽蝕及平衡盤磨損等問題進行了深
入的研究,并提出了解決辦法。
關(guān)鍵詞:給水泵 變頻調(diào)速 鍋爐 汽蝕 平衡盤磨損
[b][align=center]Effect of the Technique of Variable Frequency Governing on Safety Operation of Boiler Feed water Pump
DU Zhao hui1 XU Pei yao2
(1. Power Station , Baoding Petrochemical Plant of SINOPEC Baoding , Hebei 071051)[/align][/b]
Abstract :The energy saving principle of variable frequency governing technique for the boiler feed water pump is discussed. The problems
such as cavitation erosion and the galling of balance disc following with the variable frequency governing technique in the boiler feed water
pump are studied. Finally a suitable solution is provided.
Keywords :feed water pump variable frequency governing boiler cavitation erosion galling of balance disc
保定石油化工廠電站于1997 年對2 臺送風機、2 臺引風機改為變頻控制,經(jīng)過幾年的運行,節(jié)能效果顯著,設(shè)備運行情況良好,于是2003 年把型號為DG46 50 ×12 的2 # 給水泵改為由日本三墾公司生產(chǎn)的IPF160 K變頻器控制。運行一段時間后,節(jié)能效果也很明顯,但先后出現(xiàn)了給水泵輕度汽蝕及平衡盤嚴重磨損的問題,造成了給水泵事故跳閘1 次,縮短了2 # 給水泵的運行周期,影響了設(shè)備的安全運行及全廠的安全生產(chǎn),增加了檢修費用。經(jīng)過研究,電站修改了變頻器幾個不恰當?shù)膮?shù),更換了給水泵的平衡盤,使問題得到了解決。
1 變頻調(diào)速節(jié)能原理分析
由于許多熱電聯(lián)產(chǎn)機組都是以熱定電,負荷隨季節(jié)波動很大,而且現(xiàn)在火電機組調(diào)峰力度加大,機組的負荷變化范圍也很大,這些情況都需要實時調(diào)節(jié)給水泵的流量。目前調(diào)節(jié)給水泵流量的方式多為在出口端裝設(shè)閥門的節(jié)流調(diào)節(jié),其實質(zhì)是通過改變出口管路上的流動損失,改變管路的特性曲線,來改變水泵的工作點。由于這種調(diào)節(jié)方式多余的流量僅僅是靠調(diào)節(jié)閥節(jié)流調(diào)節(jié),而電動機的輸出功率并沒有多大改變,浪費了大量的電能。
調(diào)速節(jié)能原理可以從以下2 個方面來說明:
[b][align=center]詳細內(nèi)容請點擊:
變頻調(diào)速技術(shù)對鍋爐給水泵安全運行的影響[/align][/b]